Free Windows utility

ConvertAutomation TIA XML Exporter 0.3.13

Free local Windows utility for creating consistent Siemens TIA Portal Openness XML exports and reducing compatibility issues across conversion workflows.

Export one selected PLC block or all available PLC blocks, Tag Tables, PLC Data Types, and UDTs for documentation, analysis, and present or upcoming conversion tools.

Export the PLC objects required by engineering workflows

Selected block export

Export one selected PLC block while preserving its native Siemens Openness XML representation.

Export all PLC blocks

Export all available PLC blocks, including objects organized inside nested TIA Portal folders.

PLC Tag Tables

Export all available PLC Tag Tables as individual native Siemens Openness XML files.

PLC Data Types and UDTs

Export PLC Data Types and user-defined data types for documentation, analysis, and conversion preparation.

Local processing

Work locally on Windows without intentional project uploads by the exporter.

Problem-focused diagnostics

Create diagnostic reports only when export problems occur, instead of producing unnecessary reports for successful exports.

Recommended for consistent inputs: the online converter can accept an already compatible XML block created through another valid method, but this utility prepares files specifically for the Convert Automation workflow. Its Tag Table, PLC Data Type, and UDT exports will also support our upcoming data-structure conversion tool.

What’s new in version 0.3.13

More PLC objects

Added complete PLC Tag Table export plus PLC Data Type and UDT export.

Organized output

Added dedicated output folders for Blocks, TagTables, and PlcDataTypes.

Simplified interface

Retained single-block export and simplified the public interface to Export one block and Export all XML.

The exported XML structure is prepared for external documentation, analysis, and conversion tools while preserving native Siemens Openness XML files.

What must be ready before exporting

Windows and .NET

Use Windows 10 or Windows 11 with Microsoft .NET Framework 4.x installed.

TIA Portal V17–V21

Install Siemens TIA Portal V17 through V21 and the matching Siemens TIA Openness components.

Openness permissions

The Windows user must belong to the Siemens TIA Openness user group and have the required access to the engineering environment.

Open project

Open the target project in TIA Portal Project View before attaching the exporter. Review the selected project and block list before export.

Export one block or all supported XML objects

Open the TIA Portal projectUse Project View and confirm the correct project and PLC are available.
Run the attachment testVerify that TIA Openness can access the open engineering session.
Load the PLC block listInspect the blocks detected by the utility, including objects inside nested folders.
Choose the exportUse Export one block for the selected block or Export all XML for blocks, Tag Tables, and PLC Data Types.
Review the organized outputCheck the Blocks, TagTables, and PlcDataTypes folders and review a diagnostic report if a problem occurred.

Using the exported XML

Siemens XML exports can support source review, documentation, structured analysis, version-controlled engineering workflows, and preparation for PLC code conversion.

To create Rockwell-oriented deliverables, select one valid OB, FB, or FC XML block and upload it to the online converter. The result is a ZIP package containing the L5X output, review report, and text fallback.

Review exported data. Confirm that the expected objects were exported and that every XML file belongs to the correct project version before analysis or migration work. Protected or inconsistent objects may not be exportable.

Install the Windows utility

  1. Download the ZIP package.
  2. Extract the ZIP file.
  3. Run ConvertAutomation_TIA_XML_Exporter_Setup_0.3.13.exe.
  4. Follow the installation instructions.
  5. Open TIA Portal and load the required project in Project View.
  6. Start ConvertAutomation TIA XML Exporter.
Windows security notice
Windows may display a security warning because the installer is not digitally signed. Download the application only from the official ConvertAutomation website.

Get TIA XML Exporter 0.3.13

Version 0.3.13

The ZIP package contains the Windows installer for the current release.

File:
ConvertAutomation_TIA_XML_Exporter_Setup_0.3.13.zip

License: free proprietary
Archive format: ZIP

Used to manage utility access and understand who finds the exporter useful. See the privacy notice. Version 0.3.13

TIA XML Exporter questions

Can I export all available PLC blocks?

Yes. The utility supports exporting a selected block or the available block list and creates a report for blocks that could not be exported.

Does it upload my TIA Portal project?

No. The exporter runs locally on Windows and does not automatically upload the TIA Portal project to a cloud service.

Is it required for Convert Automation?

Not when you already have a compatible single-block XML export. It is recommended because its consistent output reduces compatibility issues, and it will be required by workflows that depend on its Tag Table, PLC Data Type, and UDT exports.

Is Siemens associated with this utility?

No. ConvertAutomation is not affiliated with, approved by, sponsored by, or supported by Siemens.

Export one OB, FB, or FC and start the conversion

Upload the individual XML block and generate the reviewable Rockwell conversion package.