Siemens to Rockwell block conversion

A faster path from TIA Portal XML to Studio 5000

Follow the complete path from one TIA Portal XML block to a ZIP conversion package. Convert Automation handles repetitive translation work while the programmer keeps control of review, import, testing, and approval.

Currently available free with no account required. Availability, limits, features, and future pricing may change.

One block, one reviewable workflow

The converter is intentionally focused on individual blocks so programmers can inspect each result and manage migration decisions in a controlled way.

1. Supply one XML block

Export one OB, FB, or FC from TIA Portal, preferably with the free TIA XML Exporter. Maximum file size is 5 MB.

2. Analyze before conversion

Review the detected block information before starting the conversion.

3. Download and inspect

Download the ZIP package, follow the import location identified in the report, then review and test the result.

Static workflow diagram from one TIA XML block to Rockwell L5X and review report
The primary path produces an L5X and review report; the ZIP also includes an ASCII fallback with supporting comments.

Input and compatibility

The converter accepts one XML export containing a single OB, FB, or FC from TIA Portal V17 through V21.

  • One OB, FB, or FC XML block per conversion
  • Maximum upload size: 5 MB
  • Compatibility varies by block type and programming language
  • Instructions and XML structure can affect conversion coverage
  • No guarantee that every block or instruction is fully supported

One ZIP conversion package

  • Rockwell L5X: the primary generated import file
  • Conversion report: review points and the appropriate import destination, such as a routine or Add-On Instruction
  • ASCII fallback with supporting comments: copy-ready backup for manual use if the L5X import fails

What happens during conversion

UploadThe service receives one authorized Siemens XML block.
AnalyzeThe block structure and available content are inspected.
ConvertSupported logic is translated into Rockwell-oriented deliverables.
ReportReview points and conversion information are presented to the programmer.
ValidateThe programmer reviews, corrects, imports, tests, and approves the result.
Built to support your expertise.
Every conversion is a starting point for engineering review, not a substitute for it. Review and test the generated files with particular attention to machine behavior and safety functions.
Uploaded file handling
XML files and generated results may be retained for up to 30 days. Private result links expire after 24 hours. Users must have authority to upload the PLC content and must not upload secrets or unauthorized data.

Check the input before you convert

Confirm the supported block types, TIA Portal versions, file-size limit, and engineering constraints on the compatibility section.

Need a consistent XML export?

The recommended Windows utility reduces compatibility issues caused by different export methods and also exports Tag Tables, PLC Data Types, and UDTs.

Start with one OB, FB, or FC XML block

Analyze, convert, download the ZIP package, then complete the engineering review.